Answer: (1) Fault phenomenon. The cooling fan trips and stops.

(2) Cause analysis.

1) Fan motor failure;

2) Fan motor thermal relay failure (aging);

3) Loose wiring;

4) Cooler blockage; Large exhaust resistance.

(3) Elimination method.

1) Check the fan motor;

2) Replace the fan motor thermal relay;

3) Check the wiring;

4) Use compressed air or water to clean the cooler.